Ventilatory Thresholds Differences According to Aerobic Fitness Level in 1450 Males and 241 Females on Cycle-Ergometer: A Cross-Sectional Study

dc.contributor.authorBenítez-Muñoz, José Antonio
dc.contributor.authorAlcocer-Ayuga, María
dc.contributor.authorCupeiro, Rocío
dc.contributor.authorGuisado-Cuadrado, Isabel
dc.contributor.authorRojo-Tirado, Miguel Ángel
dc.contributor.authorAlfaro-Magallanes, Víctor Manuel
dc.contributor.authorRomero-Parra, Nuria
dc.contributor.authorAparecida-Castro, Eliane
dc.contributor.authorRamos-Campo, Domingo J.
dc.contributor.authorArmero-Sotillo, Alberto
dc.contributor.authorPeinado, Ana B.
dc.contributor.authorBenito, Pedro J.
dc.contributor.authorAlfaro-Magallanes, Víctor M.
dc.date.accessioned2026-04-09T07:22:44Z
dc.date.issued2025-07
dc.description.abstractThe aim of the study was to analyze the influence of an aerobic fitness level on the percentage of maximum oxygen consumption, heart rate, and power output (%VO2max, %HRmax, and %Wmax) at which ventilatory thresholds 1 (VT1) and 2 (VT2) occur during a ramp incremental cycle-ergometer test in males and females considering age. 1450 males and 241 females performed a ramp incremental exercise test until exhaustion to determine VT1, VT2, and VO2max. Combining the oxygen consumption at VT1, VT2, and VO2max by clustering analysis, males were classified as a low, medium, or high aerobic fitness level and females were classified as a low or high aerobic fitness level. Results showed VO2max was very poorly correlated with the %VO2max at which VT1 and VT2 occur (r ≤ 0.115), whereas oxygen consumption at VT1 and VT2 showed a stronger positive association with the %VO2max at which VT1 and VT2 occur, respectively (r = 0.357-0.604). Furthermore, the %VO2max at which VT1 and VT2 occur were greater the higher the aerobic fitness level (all p ≤ 0.002), observing a high heterogeneity in the %VO2max at which VT1 and VT2 occur even stratifying the sample by sex and aerobic fitness levels. In conclusion, the percentage of maximum at which VT1 and VT2 occur are better related to oxygen consumption at VT1 and VT2, respectively, than to VO2max. Moreover, the common strategy consisting of establishing exercise intensity as a fixed percentage of maximum might not be effective to match intensity across individuals even if sex and aerobic fitness levels is considered. TRIAL REGISTRATION: NCT06246760.
dc.identifier.citationBenítez-Muñoz JA, Alcocer-Ayuga M, Cupeiro R, Guisado-Cuadrado I, Rojo-Tirado MÁ, Alfaro-Magallanes VM, Romero-Parra N, Aparecida-Castro E, Ramos-Campo DJ, Armero-Sotillo A, Peinado AB, Benito PJ. Ventilatory Thresholds Differences According to Aerobic Fitness Level in 1450 Males and 241 Females on Cycle-Ergometer: A Cross-Sectional Study. Eur J Sport Sci. 2025 Jul;25(7):e12323.
dc.identifier.doihttps://doi.org/10.1002/ejsc.12323
dc.identifier.issn1536-7290
dc.identifier.urihttps://hdl.handle.net/10115/193997
dc.language.isoen
dc.publisherWiley
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectVT1
dc.subjectVT2
dc.subjectheart rate
dc.subjectoxygen uptake
dc.subjectpower output
dc.titleVentilatory Thresholds Differences According to Aerobic Fitness Level in 1450 Males and 241 Females on Cycle-Ergometer: A Cross-Sectional Study
dc.typeArticle
dc.type.hasVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Name:
European Journal of Sport Science - 2025 - Benítez‐Muñoz - Ventilatory Thresholds Differences According to Aerobic Fitness.pdf
Size:
1.64 MB
Format:
Adobe Portable Document Format
Loading...
Name:
39_2025_Benítez_Manuscript accepted.pdf
Size:
568.99 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
2.96 KB
Format:
Item-specific license agreed upon to submission
Description: