Heart rate variability on 7-day Holter monitoring using a bootstrap rhythmometric procedure
| dc.contributor.author | Goya-Esteban, Rebeca | |
| dc.contributor.author | Mora-Jiménez, Inmaculada | |
| dc.contributor.author | Rojo-Alvarez, José Luis | |
| dc.contributor.author | Barquero-Pérez, Oscar | |
| dc.contributor.author | Pastor-Pérez, Francisco J | |
| dc.contributor.author | Manzano-Fernández, Sergio | |
| dc.contributor.author | Pascual-Figal, Domingo A | |
| dc.contributor.author | García-Alberola, Arcadi | |
| dc.date.accessioned | 2026-04-29T10:59:53Z | |
| dc.date.issued | 2010-02-17 | |
| dc.description.abstract | Heart rate variability (HRV) markers have been widely used to characterize the autonomous regulation state of the heart from 24-h Holter monitoring, but long-term evolution of HRV indexes is mostly unknown. A dataset of 7-day Holter recordings of 22 patients with congestive heart failure was studied. A rhythmometric procedure was designed to characterize the infradian, circadian, and ultradian components for each patient, as well as circadian and ultradian fluctuations. Furthermore, a bootstrap test yielded automatically the rhythmometric model for each patient. We analyzed the temporal evolution of relevant time-domain (AVNN, SDNN, and NN50), frequency-domain (LF, HF, HFn, and LF/HF), and nonlinear (alpha(1) and SampEn) HRV indexes. Circadian components were the most significant for all HRV indexes, but the infradian ones were also strongly present in NN50, HFn, LF/HF, alpha(1), and SampEn indexes. Among ultradian components that one corresponding to 12 h, was the most relevant. Long-term monitoring of HRV conveys new potentially relevant rhythmometric information, which can be analyzed by using the proposed automatic procedure. | |
| dc.identifier.citation | R. Goya-Esteban et al., "Heart Rate Variability on 7-Day Holter Monitoring Using a Bootstrap Rhythmometric Procedure," in IEEE Transactions on Biomedical Engineering, vol. 57, no. 6, pp. 1366-1376, June 2010, doi: 10.1109/TBME.2010.2040899 | |
| dc.identifier.doi | 10.1109/TBME.2010.2040899 | |
| dc.identifier.other | 1558-2531 | |
| dc.identifier.uri | https://hdl.handle.net/10115/199957 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Electrical and Electronics Engineers | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.title | Heart rate variability on 7-day Holter monitoring using a bootstrap rhythmometric procedure | |
| dc.type | Article |