Examinando por Autor "Fuentes, Maria Victoria"
Mostrando 1 - 2 de 2
- Resultados por página
- Opciones de ordenación
Ítem One-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlays(Springer, 2020) Souza, Joana; Fuentes, Maria Victoria; Baena, Eugenia; Ceballos, LauraTo compare the 1-year clinical performance of lithium disilicate and resin composite CAD/CAM onlay restorations. Twenty patients that required two restorations in posterior teeth, with at least one cusp to be covered, received two onlays. One was made with IPS e.max CAD (Ivoclar-Vivadent) and the other with Lava Ultimate (3M Oral Care). Two blind observers evaluated the restorations at baseline and 1 year after the onlays were cemented, according to FDI criteria. At each recall, digital photographs, bite-wing radiographs and impressions of the restorations were taken for SEM evaluation of the interface. Results were analyzed by Mann-Whitney U and Wilcoxon tests (p < 0.05). At baseline and in the 1-year recall, both CAD/CAM materials exhibited excellent results in most criteria with similar esthetic, functional and biological properties (p > 0.05). However, deterioration in surface lustre (p = 0.020) and color match/translucency (p = 0.039) were detected for IPS e.max CAD onlays after 1-year. Under SEM evaluation, there were no statistically differences in micromorphological criteria at baseline nor after a year between IPS e.max CAD and Lava Ultimate onlays. Conclusion: After 1 year of clinical service IPS e.max CAD and Lava Ultimate onlays showed a similar clinical performance that needs to be confirmed in long-term evaluations.Ítem Shear bond strength of a flash-free orthodontic adhesive system after thermal aging procedure(Medicina Oral S.L, 2019) González-Serrano, Carlos; Baena q, Eugenia; Fuentes, Maria Victoria; Albadalejo, Alberto; Contreras-Míguez, Manuel; Lagravère, Manuel O; Ceballos, LauraBackground: The aim of this study was to compare the shear bond strength (SBS) of a flash-free and precoated orthodontic adhesive with a compomer orthodontic adhesive before and after thermocycling. The adhesive remnant index (ARI) was also determined for both adhesives. Material and methods: The adhesive remnant index (ARI) was also determined for both adhesives. Material and Methods: A total of 120 human premolars were randomly divided into two groups (n=60) according to the orthodontic adhesive used: APC Flash-Free Adhesive Coated Appliance System (APC FF) or Transbond PLUS Color Change Adhesive (TP), as control. A SBS test was performed and ARI value for each specimen was also assessed. Results were analyzed by two-way ANOVA and Tukey's Chi-square test (p<0.05). Results: SBS values were significantly influenced by thermocycling (p<0.01). Neither the orthodontic adhesive nor the interaction between adhesive and thermocycling statistically affected SBS results (p>0.05). Conclusions: APC FF and TP showed similar bond strength results. Thermocycling induced a significant decrease in SBS values for the two adhesives tested, without differences between 10,000 and 20,000 thermal cycles. Moreover, APC FF left less adhesive remnants on the enamel compared to TP. Key words:APC Flash-Free, APC cement, aging, orthodontics, resin cements.