Show simple item record

Estimation of Reference Indices of Left Ventricular Chamber Function from Echocardiographic Images with Multidimensional Kernel Methods

dc.contributor.authorSantiago-Mozos, Ricardo
dc.contributor.authorRojo-Álvarez, José Luis
dc.contributor.authorAntoranz, J Carlos
dc.contributor.authorRodriguez, Daniel
dc.contributor.authorDesco, Mar
dc.contributor.authorBarrio, Alicia
dc.contributor.authorBenito, Yolanda
dc.contributor.authorYotti, Raquel
dc.contributor.authorBermejo, Javier
dc.date.accessioned2013-04-23T14:16:45Z
dc.date.available2013-04-23T14:16:45Z
dc.date.issued2012-09-09
dc.identifier.citationRicardo Santiago-Mozos, José Luis Rojo-Alvarez, J Carlos Antoranz, Daniel Rodriguez, Mar Desco, Alicia Barrio, Yolanda Benito, Raquel Yotti, Javier Bermejo "Estimation of reference indices of left ventricular chamber function from echocardiographic images with multidimensional kernel methods",Computing in Cardiology (CinC), 2012, 549-552es
dc.identifier.isbn978-1-4673-2076-4
dc.identifier.issn2325-8861
dc.identifier.urihttp://hdl.handle.net/10115/11625
dc.description.abstractAdvanced nonlinear estimation methods can compete with their linear counterparts for the estimation of left ventricular (LV) function indices from color-Doppler M-mode images. We benchmarked three methods: Support Vector Regression, Partial Least Squares and Principal Component Regression using linear and non-linear (Gaussian) kernels. Two reference indices were directly estimated from the images, namely, the peak-systolic elastance (Emax) and the time-constant of LV relaxation (Tau). We found linear methods performing slightly better for predicting Emax, an easier task, but they were outperformed by non-linear procedures when predicting Tau, a harder estimation problem.es
dc.description.sponsorshipSpanish Government under the Research Projects TEC2010-19263 from Ministerio de Ciencia e Innovación, PIS09/02603 and RD06/0010 (RECAVA) from the Instituto de Salud Carlos III, Ministerio de Economía y Competitividad. Juan de la Cierva Program of the Spanish Ministerio de Ciencia e Innovaciónn (Ref: JCI-2011-11150).es
dc.language.isoenes
dc.publisherIEEEes
dc.subjectcolor-Doppler M-mode imageses
dc.subjectleft ventricular functiones
dc.subjectestimationes
dc.subjectkernel methodses
dc.subjectmultidimensionales
dc.titleEstimation of Reference Indices of Left Ventricular Chamber Function from Echocardiographic Images with Multidimensional Kernel Methodses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.subject.unesco3325 Tecnología de las Telecomunicacioneses
dc.subject.unesco3205.01 Cardiologíaes
dc.description.departamentoTeoría de la Señal y Comunicaciones


Files in this item

This item appears in the following Collection(s)

Show simple item record

Los ítems de digital-BURJC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario