Show simple item record

A Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Falls

dc.contributor.authorGarcía‐Villamil, Guillermo
dc.contributor.authorNeira‐Álvarez, Marta
dc.contributor.authorHuertas‐Hoyas, Elisabet
dc.contributor.authorRamón‐Jiménez, Antonio
dc.contributor.authorRodríguez‐Sánchez, Cristina
dc.date.accessioned2023-12-19T14:26:15Z
dc.date.available2023-12-19T14:26:15Z
dc.date.issued2021-06-24
dc.identifier.citationGarcía-Villamil, G.; Neira-Álvarez, M.; Huertas-Hoyas, E.; Ramón-Jiménez, A.; Rodríguez-Sánchez, C. A Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Falls. Sensors 2021, 21, 4334. https://doi.org/10.3390/s21134334es
dc.identifier.issn14243210
dc.identifier.urihttps://hdl.handle.net/10115/27480
dc.descriptionIndices de Calidad: JCR (2021): SCIE 19/64 T1 Q2 Factor de impacto: 3.847es
dc.description.abstractThe high prevalence of falls and the enormous impact they have on the elderly population is a cause for concern. We aimed to develop a walking-monitor gait pattern (G-STRIDE) for older adults based on a 6-axis inertial measurement (IMU) with the application of pedestrian dead reckoning algorithms and tested its structural and clinical validity. A cross-sectional case-control study was conducted with 21 participants (11 fallers and 10 non-fallers). We measured gait using an IMU attached to the foot while participants walked around different grounds (indoor flooring, outdoor floor, asphalt, etc.). The G-STRIDE consisted of a portable inertial device that monitored the gait pattern and a mobile app for telematic clinical analysis. G-STRIDE made it possible to measure gait parameters under normal living conditions when walking without assessing the patient in the outpatient clinic. Moreover, we verified concurrent validity with convectional outcome measures using intraclass correlation coefficients (ICCs) and analyzed the differences between participants. G-STRIDE showed high estimation accuracy for the walking speed of the elderly and good concurrent validity compared to conventional measures (ICC = 0.69; p < 0.000). In conclusion, the developed inertial-based G-STRIDE can accurately classify older people with risk to fall with a significance as high as using traditional but more subjective clinical methods (gait speed, Timed Up and Go Test).es
dc.language.isoenges
dc.publisherMDPIes
dc.rightsAttribution 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectIMUes
dc.subjectAssistantes
dc.subjectFrailtyes
dc.subjectGait analysises
dc.subjectMobile appes
dc.subjectPedestrian dead reckoninges
dc.subjectTelemedicine.es
dc.titleA Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Fallses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.3390/s21134334es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution 4.0 InternacionalExcept where otherwise noted, this item's license is described as Attribution 4.0 Internacional