Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

dc.contributor.authorGarcía-Vázquez, Verónica
dc.contributor.authorMarinetto, Eugenio
dc.contributor.authorGuerra, Pedro
dc.contributor.authorValdivieso-Casique, Manlio Fabio
dc.contributor.authorCalvo, Felipe Ángel
dc.contributor.authorAlvarado-Vásquez, Eduardo
dc.contributor.authorSole, Claudio Vicente
dc.contributor.authorVosburgh, Kirby Gannett
dc.contributor.authorDesco, Manuel
dc.contributor.authorPascau, Javier
dc.date.accessioned2024-01-04T07:30:23Z
dc.date.available2024-01-04T07:30:23Z
dc.date.issued2017-09
dc.identifier.citationVerónica García-Vázquez, Eugenio Marinetto, Pedro Guerra, Manlio Fabio Valdivieso-Casique, Felipe Ángel Calvo, Eduardo Alvarado-Vásquez, Claudio Vicente Sole, Kirby Gannett Vosburgh, Manuel Desco, Javier Pascau, Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation, Zeitschrift für Medizinische Physik, Volume 27, Issue 3, 2017, Pages 218-231, ISSN 0939-3889, https://doi.org/10.1016/j.zemedi.2016.07.002.es
dc.identifier.issn0939-3889
dc.identifier.urihttps://hdl.handle.net/10115/28173
dc.descriptionThis study was supported by projects IPT-2012-0401-300000, TEC2013-48251-C2-1-R, DTS14/00192, PI-15/02121 (Ministerio de Economía y Competitividad, ISCIII), TOPUS-CM S2013/MIT-3024 (Comunidad de Madrid) and FEDER funds. We would like to acknowledge the support of the Madrid-MIT M+Vision Consortium in facilitating this study. KG Vosburgh received support from the National Center for Image Guided Therapy under NIH P41 EB015898. The authors also extend their gratitude to Medtronic, NeuroLogica Corporation, Department of Radiation Oncology at Clínica La Luz, Hospital Universitario La Paz, radiotherapy technicians at Hospital General Universitario Gregorio Marañón and Iván Balsa for their support with data acquisition. We are also grateful to the Department of Radiation Oncology at Hospital Universitario Ramón y Cajal for providing the electron density phantom, CIRS company for supplying the chemical composition of the phantom, Cristina González and Ramón Polo for providing image quality performance of the CT simulator, and Claudia de Molina and Alejandro Sisniega for technical assistance with CT artefacts. We would also like to express our sincere gratitude to the late Professor Juan Antonio Santos-Miranda for his practical and insightful suggestions regarding the task of improving IOERT procedures.es
dc.description.abstractIntraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (“O-arm”, a cone-beam CT [CBCT] system, and “BodyTom”, a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (“TrueBeam”). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.es
dc.language.isoenges
dc.publisherElsevieres
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIOERTes
dc.subjectradiotherapyes
dc.subjectintraoperative imaginges
dc.subjectdose distributiones
dc.titleAssessment of intraoperative 3D imaging alternatives for IOERT dose estimationes
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1016/j.zemedi.2016.07.002es
dc.rights.accessRightsinfo:eu-repo/semantics/embargoedAccesses