Show simple item record

One-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlays

dc.contributor.authorSouza, Joana
dc.contributor.authorFuentes, Maria Victoria
dc.contributor.authorBaena, Eugenia
dc.contributor.authorCeballos, Laura
dc.date.accessioned2024-01-23T10:48:59Z
dc.date.available2024-01-23T10:48:59Z
dc.date.issued2020
dc.identifier.citationSouza J, Fuentes MV, Baena E, Ceballos L. One-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlays. Odontology. 2021 Jan;109(1):259-270. doi: 10.1007/s10266-020-00539-3. Epub 2020 Jul 23. PMID: 32705420; PMCID: PMC7790784.es
dc.identifier.issn1618-1247
dc.identifier.urihttps://hdl.handle.net/10115/28713
dc.description.abstractTo compare the 1-year clinical performance of lithium disilicate and resin composite CAD/CAM onlay restorations. Twenty patients that required two restorations in posterior teeth, with at least one cusp to be covered, received two onlays. One was made with IPS e.max CAD (Ivoclar-Vivadent) and the other with Lava Ultimate (3M Oral Care). Two blind observers evaluated the restorations at baseline and 1 year after the onlays were cemented, according to FDI criteria. At each recall, digital photographs, bite-wing radiographs and impressions of the restorations were taken for SEM evaluation of the interface. Results were analyzed by Mann-Whitney U and Wilcoxon tests (p < 0.05). At baseline and in the 1-year recall, both CAD/CAM materials exhibited excellent results in most criteria with similar esthetic, functional and biological properties (p > 0.05). However, deterioration in surface lustre (p = 0.020) and color match/translucency (p = 0.039) were detected for IPS e.max CAD onlays after 1-year. Under SEM evaluation, there were no statistically differences in micromorphological criteria at baseline nor after a year between IPS e.max CAD and Lava Ultimate onlays. Conclusion: After 1 year of clinical service IPS e.max CAD and Lava Ultimate onlays showed a similar clinical performance that needs to be confirmed in long-term evaluations.es
dc.language.isoenges
dc.publisherSpringeres
dc.rightsAttribution 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectOdontologíaes
dc.subjectonlayes
dc.subjectCAD/CAMes
dc.subjectResin composite blockses
dc.subjectLithium disilicatees
dc.subjectclinical performancees
dc.titleOne-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlayses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1007/s10266-020-00539-3es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution 4.0 InternacionalExcept where otherwise noted, this item's license is described as Attribution 4.0 Internacional