Show simple item record

Novel smart wearable sensors based on PVDF reinforced with CNTs for human motion monitoring

dc.contributor.authorDíaz Mena, Víctor
dc.contributor.authorFernández, Xoan Xosé
dc.contributor.authorMartinez-Diaz, David
dc.contributor.authorSánchez, María
dc.date.accessioned2024-04-11T14:45:13Z
dc.date.available2024-04-11T14:45:13Z
dc.date.issued2024
dc.identifier.citationDíaz Mena, Víctor & Fernández, Xoan & Martinez-Diaz, David & Sánchez, María & Ureña, Alejandro. (2024). Novel smart wearable sensors based on PVDF reinforced with CNTs for human motion monitoring. IEEE Sensors Journal. PP. 1-1. 10.1109/JSEN.2024.3381550.es
dc.identifier.issn1558-1748
dc.identifier.urihttps://hdl.handle.net/10115/32228
dc.description10.13039/501100007511-Universidad Rey Juan Carlos (Grant Number: Ref. 2986, SMARTSENS) 10.13039/501100011033-Agencia Estatal de Investigaci?n (Grant Number: Project MULTISENS, PID2022-136636OB-I00)es
dc.description.abstractWearable strain sensors based on Poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) reinforced with carbon nanotubes (CNTs) dispersed with Triton surfactant by solvent casting are proposed. The analysis of the electrical response shows that the conductivity increases with CNT content, as expected, whereas the addition of a high content of surfactant is more efficient at low CNT contents as it forms a more efficient electrical network. An AC analysis with Electrochemical Impedance Spectroscopy was carried out, where the variation in R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">int</sub> /R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tunnel</sub> ratio with CNT and surfactant content was analyzed. This ratio shows when the electrical pathway is saturated and the electrical transport occurs mainly through the aggregates, or when the tunneling mechanism starts to take relevance. Electromechanical analysis under tensile loading shows that the sensitivity increases with decreasing the CNT content, reaching gauge factor (GF) values of around 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup> at 80-90 % strain level, higher than most of the research found in the literature. Furthermore, the electrical response under cycling loading shows similar peak and base values between consecutive cycles in a medium-term response, highlighting the robustness of the sensors. Finally, the sensors are subjected to a proof-of-concept test for finger and elbow movement monitoring, where a good agreement between the electrical and mechanical response is observed, demonstrating the applicability of the proposed materials for monitoring medium and large human movements.es
dc.language.isoenges
dc.publisherIEEEes
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectNanoparticleses
dc.subjectSmart materialses
dc.subjectElectrical propertieses
dc.subjectStrain sensorses
dc.subjectHealthcare Monitoringes
dc.titleNovel smart wearable sensors based on PVDF reinforced with CNTs for human motion monitoringes
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1109/JSEN.2024.3381550es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 InternacionalExcept where otherwise noted, this item's license is described as Atribución 4.0 Internacional