Reliability and Validity of the 10-Meter Walk Test (10MWT) in Adolescents and Young Adults with Down Syndrome

dc.contributor.authorSánchez-González, Juan Luis
dc.contributor.authorLlamas-Ramos, Inés
dc.contributor.authorLlamas-Ramos, Rocío
dc.contributor.authorMolina-Rueda, Francisco
dc.contributor.authorCarratalá Tejada, Maria
dc.contributor.authorCuesta-Gómez, Alicia
dc.date.accessioned2024-01-15T11:50:36Z
dc.date.available2024-01-15T11:50:36Z
dc.date.issued2023-03
dc.description.abstractPeople with Down syndrome (DS) have gait deficits because motor milestones are usually reached later. Decreased gait speed or reduced stride length are some of the main deficits. The main objective of the present work was to assess the reliability of the 10-Meter Walk Test (10MWT) in adolescents and young adults with DS. The objective has been to analyze the construct validity of the 10MWT with the Timed up and go (TUG) test. A total of 33 participants with DS were included. Reliability was verified by intraclass correlation coefficient (ICC). The agreement was analyzed by the Bland-Altman method. Finally, construct validity was evaluated through Pearson correlation coefficient. The 10MWT intra-rater and inter-rater reliability were good (ICC between 0.76 until 0.9) and excellent (ICC > 0.9), respectively. The minimal detectable change for intra-rater reliability was 0.188 m/s. Also, it has demonstrated moderate construct validity (r > 0.5) considering the TUG test. The 10MWT has shown high intra- and inter-rater reliability and validity in adolescent and adults with SD and a moderate construct validity between TUG test and 10MWT.es
dc.identifier.citationSánchez-González JL, Llamas-Ramos I, Llamas-Ramos R, Molina-Rueda F, Carratalá-Tejada M, Cuesta-Gómez A. Reliability and Validity of the 10-Meter Walk Test (10MWT) in Adolescents and Young Adults with Down Syndrome. Children (Basel). 2023 Mar 30;10(4):655es
dc.identifier.doi10.3390/children10040655es
dc.identifier.urihttps://hdl.handle.net/10115/28439
dc.language.isoenges
dc.rightsAttribution 4.0 Internacional*
dc.rights.accessRightsinfo:eu-repo/semantics/embargoedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject10-Meter Walk Testes
dc.subjectDown syndromees
dc.subjectgaites
dc.subjectmeasurement propertieses
dc.subjectreliabilityes
dc.subjectvalidityes
dc.titleReliability and Validity of the 10-Meter Walk Test (10MWT) in Adolescents and Young Adults with Down Syndromees
dc.typeinfo:eu-repo/semantics/articlees

Archivos

Bloque original

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Articulo_5.pdf
Tamaño:
656.03 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.67 KB
Formato:
Item-specific license agreed upon to submission
Descripción: