FriWalk robotic walker: usability, acceptance and UX evaluation after a pilot study in a real environment

dc.contributor.authorPérez-Rodríguez, Rodrigo
dc.contributor.authorMoreno-Sánchez, Pedro A.
dc.contributor.authorValdés-Aragonés, Myriam
dc.contributor.authorOviedo-Briones, Myriam
dc.contributor.authorDivan, Stefano
dc.contributor.authorGarcía-Grossocordón, Nuria
dc.contributor.authorRodríguez-Mañas, Leocadio
dc.date.accessioned2023-12-19T14:15:23Z
dc.date.available2023-12-19T14:15:23Z
dc.date.issued2019-05-08
dc.description.abstractBackground: Scientific evidence supports that prevention strategies like multicomponent physical exercise help avoiding functional decline, falls and frailty. The robotic walker FriWalk, developed within the ACANTO project, supports the execution of controlled physical activities during hospital admission to prevent functional deterioration associated to prolonged bedrest. FriWalk shows in a clinical validation study a positive relationship with improvement in physical performance, basic activities of daily living execution and frailty status. Usability, acceptance and user experience (UX) are key aspects to ease the adoption of assistive technologies in the elderly. Objective: This work pursues the evaluation of the usability, acceptance and UX of the FriWalk from the patients and clinical professionals’ perspectives. Methods: Data collected during the validation of FriWalk in a real environment have been used. Forty-two patients recruited at Getafe University Hospital (Acute Care and Orthogeriatric Units) and one clinical professional participated. SUS, TAM, UX and ad hoc questionnaires were administered. Results: Patients provided an average SUS of 52.86 and provided valuable information in the qualitative acceptance interviews. The clinical professional provided an averaged SUS and TAM of 67 and 46.6, respectively, and evaluated all UX categories as above average. Conclusions: Usability results do not qualify FriWalk as above average; the reasons explaining this have been identified and point out to the prototypical stage of the hardware. Acceptance and UX were positively evaluated and allowed the research team to propose a new organizational model to deliver the FriWalk-based prevention program. FriWalk will be soon evolved.es
dc.identifier.citationRodrigo Pérez-Rodríguez, Pedro A. Moreno-Sánchez, Myriam Valdés-Aragonés, Myriam Oviedo-Briones, Stefano Divan, Nuria García-Grossocordón & Leocadio Rodríguez-Mañas (2020) FriWalk robotic walker: usability, acceptance and UX evaluation after a pilot study in a real environment, Disability and Rehabilitation: Assistive Technology, 15:6, 718-727es
dc.identifier.doi10.1080/17483107.2019.1617795es
dc.identifier.issn1748-3107
dc.identifier.issn1748-3115
dc.identifier.urihttps://hdl.handle.net/10115/27476
dc.language.isoenges
dc.publisherTaylor & Francis onlinees
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses
dc.subjectUsabilityes
dc.subjectUser experiencees
dc.subjectAcceptancees
dc.subjectRoboticses
dc.subjectWalkeres
dc.subjectPreventiones
dc.subjectFunctional declinees
dc.subjectHospitales
dc.titleFriWalk robotic walker: usability, acceptance and UX evaluation after a pilot study in a real environmentes
dc.typeinfo:eu-repo/semantics/articlees

Archivos

Bloque original

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
FriWalk robotic walker.pdf
Tamaño:
1.29 MB
Formato:
Adobe Portable Document Format
Descripción:
Manuscrito